Fluke a3000 FC Wireless AC Current Clamp Meter
A fully functional true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect™ enabled master units, listed
below
- Measure up to 400 A ac
- Logging function for recording and saving up to 65,000 readings
- Use as a standalone meter or as part of the system
- Inrush function
Fluke a3001 FC Wireless iFlex AC
Current Meter
A true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect™ enabled
master units, listed below.
- Measure up to 2500 A ac
- Logging function for recording and saving up to 65,000 readings
- Use as a standalone meter or as part of the system
- Inrush function
Fluke a3002 FC Wireless AC/DC
Current Meter Module
Designed to be used with the i410 or i1010 ac/dc current clamps (not included with
meter). AC/DC current meter that wirelessly relays measurements from the i410 or i1010
clamp accessory to other Fluke Connect™ enabled master units, listed below.
- Measure up to 400 A ac or 400 A dc with i410 (sold separately)
- Measure up to 600 A ac or 1000 A dc with i1010 (sold separately)
- Use as a standalone meter or as part of the system
Specifications | a3000 FC | a3001 FC | a3002 FC |
Range | 0.5A to 400.0 A AC | 0.5 A to 2500 A AC | up to 600A AC and 1000 A DC (with I1010 Current Clamp) |
Resolution | 0.1 A | 0.1 A | 0.1 A |
Accuracy | 400.0 A: 2 % ± 5 digits (10 Hz to 100 Hz), 2.5 % ± 5 digits (100 Hz to 500 Hz) | 3 % ± 5 digits (5 Hz to 500 Hz) | AC:1.0%+3 DC:0.5%+3 (45Hz to 1000Hz) |
Inrush | Max displayed reading: 999.9A | ||
Crest Factor (50Hz/60Hz) | 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 % for C.F. > 2 | 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 | |
LCD w/backlight | 3½ digits | 3½ digits | 3 ½ digits, 6000 counts, 4/sec update rate |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel | 1 sec minimum/adjustable by PC or front panel | 1 sec minimum/adjustable by PC or front panel |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | 2 AA, NEDA 15 A, IEC LR6 | 2 AA, NEDA 15 A, IEC LR6 |
RF communications | 2.4 GHZ ISM Band | 2.4 GHZ ISM Band | 2.4 GHZ ISM Band |
RF communication range | Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m | Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m | Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Temperature coefficient | Add 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) | Add 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) | Add 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) |
Operating humidity | 90 % at 35 °C 75 % at 40 °C 45 % at 50 °C | 90 % at 35 °C 75 % at 40 °C 45 % at 50 °C | 90 % at 35 °C 75 % at 40 °C 45 % at 50 °C |
EMC | EN 61326-1:2013 | EN 61326-1:2013 | EN 61326-1:2013 |
Safety compliance | IEC 61010-1, CAT III 600 V, CAT IV 300 V, 3rd edition | IEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition | IEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition |
Safety rating | CAT III 600 V | CAT IV 600 V, CAT III 1000 V | CAT IV 600 V, CAT III 1000 V |
Certifications | cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE | cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE | cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating | IP30 | IP42 | IP42 |
Jaw opening | 34 mm (1.33 in) | 25.4 cm (10 in) coil | |
Size (HxWxD) | 20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) | 160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in) |